Measures in real time (every two seconds), in degrees Celsius, with the accuracy of +/- 2 degrees C, temperatures in the range (-55, 125). Encapsulated, so that it can function correctly in environments with temperature / humidity that can reach extreme values, it can also be used in monitoring special environments such as: medical or scientific laboratories, aquariums, refrigeration devices, etc ... Plug and play. RJ-11 connector. Compatible with any Room Alert server. Length 100 feet (30.48 meters).
Measure in real time (every two seconds), the temperature in degrees Celsius, with the accuracy of +/- 2 degrees C, in the range (-40, 85). Measures in real time (every two seconds), the relative humidity without condensation, with the accuracy +/- 4.5%, in the range (5%, 95%). Measures the thermal comfort index (temperature felt). Plug and play. RJ-11 connector. Compatible with any Room Alert server. Shielded cable. Length 25 feet (7.62 meters).
It signals in real time, to the Room Alert server, the water level (from a large tank), located between a configured minimum and maximum level. Level variations smaller than 10 inches (0.254 meters) are not noticed. Level variations larger than 50 inches (1.27 meters) are not noticeable. The cable and the float are adapted to the environment in which it operates. Normal condition: open. Plug and play. Standard cable length 25 feet (7.62 meters) extendable up to 900 feet (274.32 meters). Compatible with any Room Alert server.
It signals in real time, to the Room Alert server, the water level (from a large tank), located between a configured minimum and maximum level. Level variations smaller than 10 inches (0.254 meters) are not noticed. Level variations larger than 50 inches (1.27 meters) are not noticeable. The cable and the float are adapted to the environment in which it operates. Normal condition: closed. Plug and play. Standard cable length 25 feet (7.62 meters) extendable up to 900 feet (274.32 meters). Compatible with any Room Alert server.
Measure in real time (every two seconds), the temperature in degrees Celsius, with the accuracy of +/- 2 degrees C, in the range (-40, 85). Measures in real time (every two seconds), the relative humidity without condensation, with the accuracy +/- 4.5%, in the range (5%, 95%). Measures the thermal comfort index (temperature felt). Plug and play. RJ-11 connector. Compatible with any Room Alert server. Shielded cable. Length 50 feet (15.24 meters).
Signal the presence of water in real time to the Room Alert server. Plug and play. Standard cable length 25 feet (7.62 meters) extendable up to 900 feet (274.32 meters). Power a 9V Alkaline battery (included). Compatible with any Room Alert server.
It signals in real time, to the Room Alert server, the level of fuel or other viscous liquid (from a large tank), located between a configured minimum and maximum level. Level variations smaller than 10 inches (0.254 meters) are not noticed. Level variations larger than 50 inches (1.27 meters) are not noticeable. The cable and the float are adapted to the corrosive environment in which it operates. Normal condition: closed. Plug and play. Standard cable length 25 feet (7.62 meters) extendable up to 900 feet (274.32 meters). Compatible with any Room Alert server.
It signals in real time, to the Room Alert server, the level of fuel or other viscous liquid (from a large tank), located between a configured minimum and maximum level. Level variations smaller than 10 inches (0.254 meters) are not noticed. Level variations larger than 50 inches (1.27 meters) are not noticeable. The cable and the float are adapted to the corrosive environment in which it operates. Normal condition: open. Plug and play. Standard cable length 25 feet (7.62 meters) extendable up to 900 feet (274.32 meters). Compatible with any Room Alert server.
Measure in real time (every two seconds), the temperature in degrees Celsius, with the accuracy of +/- 2 degrees C, in the range (-40, 85). Measures in real time (every two seconds), the relative humidity without condensation, with the accuracy +/- 4.5%, in the range (5%, 95%). Measures the thermal comfort index (temperature felt). Plug and play. RJ-11 connector. Compatible with any Room Alert server. Shielded cable. Length 100 feet (30.48 meters).
It signals in real time, to the Room Alert server, the presence of fluids that come in contact with the sensor cable. Plug and play. 5VDC 1A DC adapter. Compatible with any Room Alert server. Length 24 feet (7,3152 meters).
It signals in real time, to the Room Alert server, the presence of fluids that come in contact with the sensor cable. Plug and play. 5VDC 1A DC adapter. Compatible with any Room Alert server. Length 50 feet (15.24 meters).
Server for monitoring temperature, humidity, current, energy consumption, floods, smoke, fire, access, etc ... Internal sensor: temperature. External sensor (included in the basic package): Digital sensor for active power and temperature. Software included: Device ManageR Software, One year free upgrade to RoomAlert.com account. 3 ports for external temperature or temperature and humidity sensors. 4 ports for external sensors: smoke, flood, current, movement, open door, air flow, water level. 1 relay port (switch). 1 signal tower port (light tower adapter required). 1 10/100 ethernet port; POE (Power Over Ethernet). Web interface for administration. Email notifications. SNMP. Made in USA.
Server for monitoring temperature, humidity, current, energy consumption, floods, smoke, fire, access, etc ... Internal sensor: temperature. External sensor (included in the basic package): Digital sensor for active power and temperature. Software included: Device ManageR Software, One year free upgrade to RoomAlert.com account. 3 ports for external temperature or temperature and humidity sensors. 4 ports for external sensors: smoke, flood, current, movement, open door, air flow, water level. 1 relay port (switch). 1 signal tower port (light tower adapter required). 1 10/100 ethernet port; Mount in a 19 '' rack. POE (Power Over Ethernet). Web interface for administration. Email notifications. SNMP. Made in USA.
Server for monitoring temperature, humidity, current, energy consumption, floods, smoke, fire, access, etc ... Internal sensor: temperature. External sensor (included in the basic package): Digital sensor for active power and temperature. Software included: Device ManageR Software, One year free upgrade to RoomAlert.com account. 3 ports for external temperature or temperature and humidity sensors. 4 ports for external sensors: smoke, flood, current, movement, open door, air flow, water level. 1 relay port (switch). 1 signal tower port (light tower adapter required). 1 10/100 ethernet port; POE (Power Over Ethernet). Web interface for administration. Email notifications. SNMP. Web interface for administration (https). Email notifications (SSL / TLS). SNMP V1 and V2 (soon V3). Made in USA.
Server for monitoring temperature, humidity, current, energy consumption, floods, smoke, fire, access, etc ... Internal sensor: temperature. External sensors (included in the basic package): Digital sensor for active power and temperature 7m, Digital temperature and Air flow, Flood sensor with cable 2.4, Digital Active Power and Room entry sensor. Software (included in the basic package) 1 RoomAlert.com basic account, 1 an RoomAlert.com Professional Account Upgrade. 3 ports for external temperature or temperature and humidity sensors. 4 ports for external sensors: smoke, flood, current, movement, open door, air flow, water level. 1 relay port (switch). 1 signal tower port (light tower adapter required). 1 10/100 ethernet port; Mount in a 19 '' rack. POE (Power Over Ethernet). Web interface for administration. Email notifications. SNMP. Web interface for administration (https). Email notifications (SSL / TLS). SNMP V1 and V2 (soon V3). Made in USA.
Server for monitoring temperature, humidity, current, energy consumption, floods, smoke, fire, access, etc ... Internal sensor: temperature. External sensors (included in the basic package): Digital sensor for active power and temperature 7m, Digital temperature and Air flow, Flood sensor with cable 2.4, Digital Active Power and Room entry sensor. Software (included in the basic package) 1 RoomAlert.com basic account, 1 an RoomAlert.com Professional Account Upgrade. 3 ports for external temperature or temperature and humidity sensors. 4 ports for external sensors: smoke, flood, current, movement, open door, air flow, water level. 1 relay port (switch). 1 signal tower port (light tower adapter required). 1 10/100 ethernet port; Mount in a 19 '' rack. POE (Power Over Ethernet). Web interface for administration. Email notifications. SNMP. Web interface for administration (https). Email notifications (SSL / TLS). SNMP V1 and V2 (soon V3). Made in USA.
Server for monitoring temperature, humidity, current, energy consumption, floods, smoke, fire, access, etc... Internal sensor: temperature. External sensors (included in the basic package): Digital temperature and humidity sensor 7m, Digital temperature and air flow sensor, Flood sensor with 7.3m cable, Active power sensor, 2 x RoomEntry sensor, MUPS sensor. Accessories included: signal tower and adapter, 2 x flood protection kit (small). Software (included in the basic package) 1 RoomAlert.com basic account, 1 year RoomAlert.com Professional Account Upgrade. 3 ports for external temperature or temperature and humidity sensors. 4 ports for external sensors of: smoke, flood, current, movement, open door, air flow, water level. 1 relay port (switch). 1 signal tower port (light tower adapter is required). 1 10/100 ethernet port; Mounting in a 19" rack. POE (Power Over Ethernet). Web interface for administration (https). Email notifications (SSL/TLS). SNMP V3. Made in USA.