Search

Room Alert 3S-Server monitoring temperature, humidity, current

Server for monitoring temperature, humidity, current, energy consumption, floods, smoke, fire, access, etc... Internal sensor: temperature. 1 basic RoomAlert.com cloud account. 1 port for external temperature or temperature and humidity sensor. 1 port for external sensor of: smoke, flood, current, movement, open door, air flow, water level. 1 10/100 ethernet port; POE (Power Over Ethernet). Web interface for administration. Email notifications. Web interface for administration (https). Email notifications (SSL/TLS). SNMP V1, V2 and V3. Made in USA.
Manufacturer: Room Alert
Availability: In stock
SKU: RA3S-ES0-BAS
1.502,34 RON incl tax
1.503,33 RON incl tax
decrease increase

Room Alert 3S is a server for monitoring temperature, humidity, current, energy consumption, floods, smoke, fire, access, etc ...

 


 

Room Alert 3S servers are designed to monitor the environment by:

  • Measuring temperature, humidity and current.
  • Detecting the occurrence of unforeseen events or situations that may compromise the processes that take place in the monitored environment. For example.:
    • Smoke / fire;
    • Stopping airflows (ventilation);
    • Unwanted presence of water (floods);
    • Increasing or decreasing the level of water or fuel;
    • Power failure;
    • Access to monitored premises;
  • Automatic or controlled real-time corrective actions.
  • Notifications to the persons responsible for monitoring type:
    • Room Alert.com account - Accessible from anywhere and from any device (Smatphone, SmartWatch, Smart TV, Tablet, PC, Notebook);
    • email
    • EMail to SMS;
    • SMS - Optional via a GSM modem;
    • Embedded Web page;
    • Centralized monitoring software - Device Manager;
    • Light and sound signals;

This Romm Alert server is a device that can be connected to the IT network, which receives real-time data from connected sensors (internal / external).
The data received from the sensors are displayed in real time in the integrated web page of the equipment and also sent to the RoomAlert.com portal.
Alerts, notifications and automatic actions can be configured on the equipment administration web page.

The main features of this Room Alert 3S monitoring system are:

 

  • Web Interface for Administration (https);

  • Email notifications (SSL / TLS);

  • SNMP V1, V2 and V3;

  • Made in USA;

Room Alert 3S is a server for monitoring temperature, humidity, current, energy consumption, floods, smoke, fire, access, etc ...

 


 

Room Alert 3S servers are designed to monitor the environment by:

  • Measuring temperature, humidity and current.
  • Detecting the occurrence of unforeseen events or situations that may compromise the processes that take place in the monitored environment. For example.:
    • Smoke / fire;
    • Stopping airflows (ventilation);
    • Unwanted presence of water (floods);
    • Increasing or decreasing the level of water or fuel;
    • Power failure;
    • Access to monitored premises;
  • Automatic or controlled real-time corrective actions.
  • Notifications to the persons responsible for monitoring type:
    • Room Alert.com account - Accessible from anywhere and from any device (Smatphone, SmartWatch, Smart TV, Tablet, PC, Notebook);
    • email
    • EMail to SMS;
    • SMS - Optional via a GSM modem;
    • Embedded Web page;
    • Centralized monitoring software - Device Manager;
    • Light and sound signals;

This Romm Alert server is a device that can be connected to the IT network, which receives real-time data from connected sensors (internal / external).
The data received from the sensors are displayed in real time in the integrated web page of the equipment and also sent to the RoomAlert.com portal.
Alerts, notifications and automatic actions can be configured on the equipment administration web page.

The main features of this Room Alert 3S monitoring system are:

 

  • Web Interface for Administration (https);

  • Email notifications (SSL / TLS);

  • SNMP V1, V2 and V3;

  • Made in USA;

Products specifications
Internal sensors
Integrated temperature sensor1
Integrated humidity sensor0
Integrated current sensor0
Other specifications
Hardware Specifications.
StockEnough stock
Batteries (Mini UPS)Optional
19 '' Rack MountNot
The ambient temperature required for the server to function properlyfrom -40 degrees Celsius to 85 degrees Celsius
Relative humidity (no condensation) of the environment for the correct operation of the serverfrom 5% to 85% RH
Power source5 VDC 1A adapter (included)
Power supply110/240 VAC, 50/60 Hz, RoHS
On / Off ButtonNot
Reset Button (Restore To Default Settings)Yes
Optional mini UPSYes (product code: RMA-MUPS-SEN)
Mini UPS Led Condition (Battery Red / Current Green)Not
Web Server Specifications (Embedded).
Built-in (no other Server / PC required)Yes
Interface accessible through a Web Browser (Edge, IE, Chrome, Firefox, Opera, Safari)Yes
Password protectedYes
Embedded web server alerting methodsEmail, SMS, SNMP, Web
Types of destination alertsIndividual, Grouped, Hierarchical
Ping to other network equipmentNot
Graphic display of sensor statusYes
Real-time display of digital temperatureYes
Display of temperature valuesYes (Celsius and Fahrenheit)
Real-time display of digital humidityYes
Displaying digital humidity valuesYes (relative humidity percentage)
Thermal comfort index calculated and displayedYes (Celsius or Farenheit)
Real-time alerts for measured valuesYes
Digital sensors (Internal and external).
Guarantee3 years
Software included in the basic package
Basic cloud account included1
Professional cloud account included1 year
Network
Wireless (WiFi)Not
POE1
Led PoE status (Power Over Ethernet)Yes
Led WLAN status (Wi FI)Not
Ethernet port and speedRJ-45, 10/100 Mbps BaseTX
Led connection and Ethernet activityYes
Ethernet cable includedNot
Ports
Ports for digital sensors1
Ports for contact sensors1
Relay ports0
Analog ports (0-5V)0
Protocols
HTTPS web interfaceNot, Yes
SSL / TLS Email AccountsYes, Not
SNMP (Trap & Query)Yes, Yes
Easy firmware updatesYes
Compatible with SNMP monitoring applicationsYes
Logging data from sensors in real time using:Device ManageR and SNMP
Real-time sensor data feedsHTTP, SNMP, JSON, AJAX
MIB files availableYes
Product Files
User Manual / Installation Notes (PDF Files)
Planning Worksheet (PDF Files)
Write your own review
  • Only registered users can write reviews
*
*
Bad
Excellent
*
*
*
Products specifications
Internal sensors
Integrated temperature sensor1
Integrated humidity sensor0
Integrated current sensor0
Other specifications
Hardware Specifications.
StockEnough stock
Batteries (Mini UPS)Optional
19 '' Rack MountNot
The ambient temperature required for the server to function properlyfrom -40 degrees Celsius to 85 degrees Celsius
Relative humidity (no condensation) of the environment for the correct operation of the serverfrom 5% to 85% RH
Power source5 VDC 1A adapter (included)
Power supply110/240 VAC, 50/60 Hz, RoHS
On / Off ButtonNot
Reset Button (Restore To Default Settings)Yes
Optional mini UPSYes (product code: RMA-MUPS-SEN)
Mini UPS Led Condition (Battery Red / Current Green)Not
Web Server Specifications (Embedded).
Built-in (no other Server / PC required)Yes
Interface accessible through a Web Browser (Edge, IE, Chrome, Firefox, Opera, Safari)Yes
Password protectedYes
Embedded web server alerting methodsEmail, SMS, SNMP, Web
Types of destination alertsIndividual, Grouped, Hierarchical
Ping to other network equipmentNot
Graphic display of sensor statusYes
Real-time display of digital temperatureYes
Display of temperature valuesYes (Celsius and Fahrenheit)
Real-time display of digital humidityYes
Displaying digital humidity valuesYes (relative humidity percentage)
Thermal comfort index calculated and displayedYes (Celsius or Farenheit)
Real-time alerts for measured valuesYes
Digital sensors (Internal and external).
Guarantee3 years
Software included in the basic package
Basic cloud account included1
Professional cloud account included1 year
Network
Wireless (WiFi)Not
POE1
Led PoE status (Power Over Ethernet)Yes
Led WLAN status (Wi FI)Not
Ethernet port and speedRJ-45, 10/100 Mbps BaseTX
Led connection and Ethernet activityYes
Ethernet cable includedNot
Ports
Ports for digital sensors1
Ports for contact sensors1
Relay ports0
Analog ports (0-5V)0
Protocols
HTTPS web interfaceNot, Yes
SSL / TLS Email AccountsYes, Not
SNMP (Trap & Query)Yes, Yes
Easy firmware updatesYes
Compatible with SNMP monitoring applicationsYes
Logging data from sensors in real time using:Device ManageR and SNMP
Real-time sensor data feedsHTTP, SNMP, JSON, AJAX
MIB files availableYes
Customers who bought this item also bought

Temperature and humidity sensor-7m

RMA-DTH-SEN
Measure in real time (every two seconds), the temperature in degrees Celsius, with the accuracy of +/- 2 degrees C, in the range (-40, 85). Measures in real time (every two seconds), the relative humidity without condensation, with the accuracy +/- 4.5%, in the range (5%, 95%). Measures the thermal comfort index (temperature felt). Plug and play. RJ-11 connector. Compatible with any Room Alert server. Length 25 feet (7.62 meters).
499,98 RON incl tax 500,31 RON incl tax
Filters
Sort
display